Electrical technician/maintenance at Top polymers Nigeria limited (2018-04 – 2019-05)
- Mounted control panels for single/3phase motors respectively
- Changed fuses in the substation when they got burned
- Using a contactor and overload relay we designed a control system for a single phase motor with stop and start button
- Carried out daily maintenance/ monthly inspections on each machine to avoid a sudden breakdown and to increase the life span of machines
Electrical technician/maintenance at Best premier hotel (2021-01 – 2022-01)
- Worked with "best premier hotel" on the installation of 250kv generator
- Managed the maintenance of pole mounted substation and 250kv generator
- Installed motor control for pressure pump
- Maintenance of electrical equipments like Aire conditioner, motor control panel, generator and so on
- Carried out weekly/monthly maintenance on motors, control panel, and other electrical appliances
Electrical technician/Maintenance/assembler at Skipper ets electric limited (2023-01 – 2025-05)
- Worked with skipper ETS electric limited on the production and assembled of 100kva to 15mva distribution transformes
- Successfully installed and commissioned 15Mva at sabo substation, Lagos State
- Successfully completed and commissioned also 15Mva at beta glass company limited, Delta State
- Completed the installation and commissioning of 15Mva at Eko electric distribution company v.i, Lagos State
- Carried out various transformer testing using testing equipments
- Maintained the company pole-mounted substation, which includes carrying out earthing test for proper earth improvement, checked the transformer oil gauge/breather monthly
- Carried out weekly/monthly maintenance on transformer vacuum tube motors, oil filteration machine, transformer testing kits, high voltage testing transformer, low voltage testing injection kits and so on
- We successfully installed panels like, incomers, outgoing, and bus riser panels at iyanoba substation, Lagos State
- We Installed 60kv solar grid in ibadan Nigeria
- We Installed 50watts solar panels for customers
Electrical engineer/maintenance at African steel Mills(Nig) Ltd (2025-05 – Present)
- Worked with OEM on the succe(Energy Management and Metering System) for 901 and 903 substation
- Managed the maintenance of 7.5MVA, 6MVA, 4MVA and 3MVA power transformers onsite
- Resolved short circuit fault on 800KVAR reactive power compensation panel (capacitor bank panel)
- Resolved voltage fluctuation issue on MASS-TECH float cum boost charger
- Installed 3KVA Vertiv-liebert UPS/ inverter/battery system for substation use
- Conducted quarterly break down voltage test BDV on all transformer insulating oil across site and documented results for audit purposes
- Resolved heater fault on transformer oil filtration machine replacing 5 Nos of 3.6 KW faulty heaters
- Installed a bustie system for 901 and 903 incoming supply utilizing two motorized isolators interlocked with an ABB VBF circuit breaker for safety reasons
- Installed 7.5mva transformer
- Designed and built an indoor ht panel for incoming voltage
- Good in automation and control (PLC DCS SCADA)
- Installed variable frequency drive(vfd) panels for motors drive, soft starts and speed control
- Designed and built a panel for overhead crane control (crossed train) using a contactors, overload relay timers and master control
- Designed and built a panels for "direct online starter" (dols), "star Delta starter" and "forward and reverse" for motors using a contactors, overload relay and timer relay