Skip to main content
Thomas Reynolds

Thomas Reynolds

QC Laboratory Technician

Talent
Pryor CreekMember since October 5, 2026
Packaged and split systems residential and commercial and industrial.Air and water source heat pumps and condensers.Air and water cooled chillers.Boilers and air handlers and direct fire units.Technical troubleshooting mechanical and electrical controls including controls/Technical documentation and data collection.Visual inspection of equipment and processes.Compressors including: Copeland scroll and reciprocating and semi hermetic.
·

Hire this person

Send a job offer directly to this candidate

Packaged and split systems residential and commercial and industrial.Air and water source heat pumps and condensers.Air and water cooled chillers.Boilers and air handlers and direct fire units.Technical troubleshooting mechanical and electrical controls including controls/

About

Results-driven HVAC professional with expertise in troubleshooting, compliance, and team collaboration. Proven ability to enhance system performance and mentor junior technicians, contributing to successful project outcomes.

Experience

QC Laboratory Technician - RAE Corporation - Pryor, OK

(2022-09)

  • Air-cooled, water-cooled or even evaporative cooled chillers with capacities up to 400 tons with package pump skids.
  • Condensing Units with single, dual, or multiple compressor arrangements with air-cooled or evaporative cooled systems up to 400 tons.
  • Condensing units up to 100 HP with ranges from high temp +20 degrees to low temp -20 degrees.
  • Testing RSI Refrigeration Systems Inc.
  • Testing Century Systems Inc.
  • Testing TSI Technical Systems Inc.
  • Air cooled and water-cooled chillers and heat pumps up to 240 tons. Closed and open loop pump packages. Fluid coolers and air cooled condensers.
  • Mentored junior Technicians on best practices in HVAC/R and implementation of manufacturing instructions.
  • Alignment of split coupled pumps.
  • Programmed and troubleshot Variable frequency drives for supply fans and Compressors and Condenser fans and pumps (motors). Including ABB and Invertek and Yaskawa and Mitsubishi and Danfoss and Eaton and Allen Bradley and Schneider and Emerson.
  • Programmed and troubleshot Controllers for MCS and Carel and Emerson CPC and CRX and Automated Logic.
  • Helped transition the company over to meet rules and regulations of compliance with ASHRAE standard 34 with testing of A2L refrigerants for certification listing.
  • Helped with UL classifications for low noise and power consumption listings.
  • Led cross-functional teams in the successful execution of complex HVAC projects, fostering a collaborative work environment.
  • Conducted quality control tests to ensure compliance with industry standards and specifications.
  • Participated in professional development workshops and conferences to continuously expand technical expertise within the field of HVAC engineering.
  • Analyzed test results and documented findings for laboratory reports and audits.
  • Conducted routine maintenance on heating and cooling equipment, enhancing system efficiency and longevity.

PRODUCT DESIGN ANALYST - AAON INC. - Tulsa, OK

(2005-05 - 2022-09)

  • Tested air cooled and water cooled systems from 2 - 240 tons and evaporative condenser systems from 10 - 320 tons.
  • Tested boilers and direct fire units up to 1,000,000 BTUs.
  • Started and helped instruct the Aaon Technical Academy to the testing technicians and service technicians, with experience when installing, servicing, and maintaining AAON equipment.
  • Tested and maintained commercial and industrial packaged and split systems, chillers and boilers and direct fire furnaces and air source and water source heat pumps and evaporative cooled equipment from ranges (2 - 440 tons) and 24,000 - 1,000,000 BTUs).
  • Mentored test technicians in best practices for system performance and troubleshooting, fostering professional growth within the team.
  • Ensured rigorous quality control measures were applied during production and testing, while maintaining high standards of workmanship across all projects.
  • Collaborated with research and development in the NAIC Lab thermal and acoustic performance testing under full environmental load conditions from -20°F to 130°F for HVAC equipment up to 540 tons.
  • Setup and performed customized testing capabilities including up to 8 inches per hour of rain, up to 2 inches per hour of snow, and up to 50 mph of wind.
  • Troubleshot complex issues related to HVAC systems during installation or post-project phases, delivering prompt resolutions that minimized downtime impacts.
  • Participated in professional development workshops and conferences to continuously expand technical expertise within the field of HVAC engineering.
  • Maintained up-to-date knowledge on industry trends, codes, regulations, and best practices to ensure compliance throughout project lifecycles.
  • Helped R & D meet certification standards of the governing body for the HVAC industry, the Air-Conditioning, Heating, and Refrigeration Institute (AHRI).

Education

No Degree - Quality - Tulsa Community College (2014)

Associates of Occupational Studies - HVAC/R & PLC's - Vatterott College (2005-03)

No Degree - OSU Okmulgee (2003-04)